Goal

Build the web UI as a clinical working tool that preserves the MATLAB workflow while removing the MATLAB-era visual friction. The first release should favor parity and operator confidence over decorative redesign.

Frame Inventory

Frame Timestamp Content Screen
frame-001.jpg 0:00 MATLAB main screen / EPPA logo Home
frame-002.jpg 0:30 Marker capture with loaded image Marker Capture
frame-003.jpg 1:15 Anterior analysis — markers + grid Analysis Anterior
frame-004.jpg 2:30 Anterior results table filled Analysis Anterior (results)
frame-005.jpg 3:20 Posterior analysis — 4 regions Analysis Posterior
frame-006.jpg 4:45 Lateral derecha — tangent tools Analysis Lateral R
frame-007.jpg 5:30 Lateral izquierda — results Analysis Lateral L
frame-008.jpg 7:00 Excel export dialog Export
frame-009.jpg 8:00 Manual measurement tools Manual Tools

Screens To Preserve

1. Home / Main Menu

  • Primary action: marker capture.
  • Four analysis entries: anterior, posterior, lateral right, lateral left.
  • Must make EPPA/LABIS identity visible without turning the first screen into marketing.
  • Required data-testid: btn-marker-capture, btn-vista-anterior, btn-vista-posterior, btn-vista-lateral-derecha, btn-vista-lateral-izquierda.
  • Reference frame: frame-001.jpg.

2. Marker Capture

  • Open patient image.
  • Enter patient ID.
  • Choose view from a modal/list after image upload.
  • Select marker by view from dropdown.
  • Place marker on image canvas.
  • Show marker table with marker, view, X, Y.
  • Delete selected row.
  • Save/export marker set.
  • Exit/back to main screen.
  • Required data-testid: image-display-area, markers-table, input-markers-file.
  • Reference frame: frame-002.jpg.

3. Analysis by View (x4: anterior, posterior, lateral-derecha, lateral-izquierda)

  • Left tool rail:
  • Open image (Abrir Imagen).
  • Import markers (Importar Marcadores) — CSV and .mat.
  • Calibration grid (Calibracion Grilla).
  • Reference lines (Rectas de Referencia).
  • Clear image (Limpiar Imagen).
  • Manual measurement tools (see below).
  • Center workspace:
  • Patient image with zoom/pan.
  • Visible markers (green dots).
  • Calibration grid overlay.
  • Reference line (LRV) overlay.
  • Calibration factor display (FC: X.XX cm/px).
  • LRV position display (LRV X: XXX px).
  • Right results panel:
  • Region analysis buttons: Cervico-Cefalica, Tronco-Columna, Escapular-MS / Pelvica, Pie-Tobillo.
  • Results table: Region, Variable, Medicion, Diagnostico.
  • Export button (Exportar / Exportar Tabla CSV).
  • Next view / Exit buttons.
  • Required data-testid: image-display-area, markers-table, analysis-results-table, mouse-coordinates.
  • Reference frames: frame-003 through frame-007.

4. Manual Measurement Tools (lateral views add tangent controls)

  • Angle relative to horizontal.
  • Angle relative to vertical.
  • Distance measurement.
  • Named manual measurement entry.
  • Tangent capture for head/back/sacrum (lateral only).
  • Reference frame: frame-009.jpg.

5. Export

  • One workbook per subject/session.
  • One sheet per view.
  • Columns: Region, Variable, Medicion, Diagnostico.
  • Preserve "Punto no visible" when required markers are missing.
  • Reference frame: frame-008.jpg.

Visual Direction

  • Use a quiet clinical workspace: light neutral background, high contrast text, compact controls, no large hero blocks.
  • Prefer a three-zone layout for analysis: left tools, center image, right results.
  • Icons: Lucide icon set. Key mappings:
  • ImagePlus — open image.
  • FileInput — import markers.
  • Grid3X3 — calibration grid.
  • Ruler — reference lines.
  • Eraser — clear image.
  • Download — export.
  • ArrowRight — next view.
  • Home — exit to main.
  • Crosshair — manual measurement.
  • Restrained color:
  • Blue (#2563eb) — reference lines, active tools.
  • Green (#16a34a) — placed markers.
  • Amber (#d97706) — validation warnings.
  • Red (#dc2626) — errors only.
  • Dense, readable tables. Keyboard-friendly (Tab, Enter, Escape).
  • Do not hide clinical actions behind decorative cards.
  • Density: clinical data should be scannable at a glance. No whitespace-heavy layouts.

v0 Prompt — Full Application

Create a Next.js/React clinical web application for EPPA (Evaluacion
Posturografica de Pie Automatizada). Preserve the MATLAB workflow shown
in the reference frames: marker capture, four analysis views, image
workspace with grid/reference lines/green markers, left tool rail, right
results table, manual measurement tools, and Excel export.

Use a restrained clinical design: light neutral background, compact
controls, high contrast typography, Lucide icons, dense tables,
accessible dialogs, and responsive desktop-first layout with a usable
tablet/mobile fallback. Do not create a marketing landing page.

Tech: Next.js 15 + React 18 + Radix UI + Tailwind CSS. FastAPI backend
for calculations. Cypress/Playwright for E2E. TypeScript throughout.

v0 Prompts — Per Screen

Home

Clinical tool home page. Title "EVALUACIÓN POSTUROGRÁFICA" in blue-700.
Subtitle "Sistema EPPA". Five action buttons: "Captura de Marcadores"
(primary), "Vista Anterior", "Vista Posterior", "Vista Lateral Derecha",
"Vista Lateral Izquierda". Compact grid layout. No hero image. No
marketing copy. LABIS/UBA footer credit.

Marker Capture

Marker capture screen with left controls and right image canvas.
Controls: patient ID input, "Abrir" image button, view selector dropdown
per view type, marker dropdown by selected view, "Borrar" and "Guardar"
buttons. Canvas: shows loaded image with click-to-place green markers.
Below canvas: marker table (marker name, view, X, Y) with row selection
and delete. Top nav: "PANTALLA PRINCIPAL" button.

Analysis View (template for all 4 views)

Three-zone analysis layout:
Left rail (200px): Open Image, Import Markers, Calibration Grid,
Reference Lines, Clear Image, region analysis buttons (Cervico-Cefalica,
Tronco-Columna, etc.), manual measurement tools.
Center: patient image with zoom/pan, green marker dots, blue reference
line, calibration grid overlay. FC and LRV indicators below image.
Right panel (350px): Results table (Region, Variable, Medicion,
Diagnostico), Export CSV button, navigation buttons.
Dense clinical density. No decorative elements.

Recraft/Figma Decisions

  • Recraft: Use for generating icons only if Lucide does not have the needed glyph. Do not generate full layouts in Recraft.
  • Figma: Use for high-fidelity mockups ONLY after v0 generates a working prototype. Figma is review/polish, not starting point.
  • Priority: Code-first (v0 → working Next.js), then Figma for refinement.

Component Inventory

Component Status data-testid Notes
Home buttons (5) Implemented btn-* All working
Image display area Implemented image-display-area With zoom/pan
Marker table Implemented markers-table Dense layout
Results table Implemented analysis-results-table 4-column clinical
Calibration grid Implemented Click-two-points
Reference line Implemented Click-two-points
CSV export Implemented 4-column header
Mouse coordinates Implemented mouse-coordinates Shown during tools
.mat import Implemented Via file chooser
Manual measurement Implemented Anterior, posterior and lateral views support named horizontal angle, vertical angle and distance rows
Tangent capture Implemented Lateral derecha/izquierda capture cabeza, dorsal and sacro vertical tangents
Excel export (.xlsx) NOT IMPLEMENTED See #13
"Punto no visible" NOT IMPLEMENTED See #5

E2E Baseline Coverage

Screenshots captured by Playwright visual-baseline.spec.ts and Cypress 06-video-parity-baseline.cy.ts:

  • Home (desktop/tablet/mobile) ✅
  • Marker capture with image ✅
  • Anterior with markers ✅
  • Posterior with markers ✅
  • Lateral derecha with markers ✅
  • Lateral izquierda with markers ✅

Implementation Traceability

This brief is now tied to the merged UI implementation rather than standing as a generic design document.

Merged implementation evidence:

  • 5ce1c62 / PR #83: integrated the real EPPA UI workflows on main.
  • src/app/page.tsx: home/menu with btn-marker-capture, btn-vista-anterior, btn-vista-posterior, btn-vista-lateral-derecha, and btn-vista-lateral-izquierda.
  • src/app/marker-capture/page.tsx: marker-capture workflow with image upload, view selection, marker placement, marker table, delete, save, and return-home actions.
  • src/app/analysis/anterior/page.tsx, src/app/analysis/posterior/page.tsx, src/app/analysis/lateral-derecha/page.tsx, src/app/analysis/lateral-izquierda/page.tsx: four MATLAB-equivalent analysis screens.
  • src/components/orthoposture/image-display-area.tsx: shared clinical image workspace with image, markers, overlays, tangents, and mouse-coordinates.
  • src/components/orthoposture/analysis-markers-table.tsx, src/components/orthoposture/points-table.tsx: dense marker tables exposed as markers-table.
  • src/components/orthoposture/anterior/anterior-results-panel.tsx, src/components/orthoposture/posterior/posterior-results-panel.tsx, and lateral result tables: clinical rows exposed as analysis-results-table.
  • playwright/e2e/home-parity.spec.ts, playwright/e2e/marker-capture-parity.spec.ts, playwright/e2e/unified-layout.spec.ts, playwright/e2e/visual-baseline.spec.ts, playwright/e2e/analysis-parity.spec.ts, playwright/e2e/export-parity.spec.ts: screenshot, navigation, marker, layout, numeric, and export parity checks.

Remaining explicitly out of #7 scope:

  • .xlsx workbook parity remains tracked by #13.
  • Missing-marker "Punto no visible" behavior remains tracked by #5.

Accessibility

  • All interactive elements must have accessible labels.
  • Tables must use <th> headers with scope.
  • Dialogs must trap focus and support Escape to close.
  • Color is not the only indicator — use icons + text for states.
  • Minimum contrast ratio: 4.5:1 for text.

Acceptance Criteria

  • [x] Every MATLAB action visible in the video has a web equivalent or an explicit "not implemented" issue.
  • [x] The four analysis screens share a consistent layout and differ only by view-specific marker/variable content.
  • [x] Results table can show region, variable, measurement, diagnosis for all calculated outputs.
  • [ ] Missing markers produce visible validation states and "Punto no visible" outputs where MATLAB does (see #5).
  • [x] Cypress/Playwright screenshots cover home, marker capture, all four analysis views, and export trigger.
  • [x] Frame inventory maps each video frame to a screen.
  • [x] v0 prompts are ready for each screen type.
  • [x] Component inventory tracks implementation status.